Determination of Undrained Shear Strength



Standard Penetration Test (SPT). The standard penetration resistance value NSPT , often referred to as the blowcount, is frequently used to estimate the relative density of cohesionless soil. NSPT is the number of blows required to drive a standard splitspoon sampler (1.42" I.D., 2.00" O.D.) 1 ft. The split spoon sampler is driven by a 140-lb hammer falling 30 inches. The sampler is driven 18 inches and blows counted for the last 12 inches. NSPT may be determined using standard method ASTM D 1586.



Undrained Shear Strength in KSF can be calculated as:

CU = 0.12NSPT




Try Our Message Board


Bringing Efficiency to the Construction Industry
EPC Server.com
Copyright © 2001,2002, EPCServer.com All rights reserved. All content in this site is provided 'as is' and no warranty is given as to the accuracy or suitability of any part hereof. No liability will be accepted for any direct or consequential losses, howsoever caused, following the use or misuse of any advice or information, real or implied, provided by this site.