WEIGHT OF GROUTED MASONRY WALLS



The following values are based on normal-weight hollow masonry units. Normal-weight units are assumed to have an oven-dry weight of concrete of 145 pounds per cubic foot. Weights of lighter-weight units may be obtained by direct proportion to the lighter weight of concrete being used. Values provided are in lbs/ft2

Spacing of Grouted Cells Nominal Wall Thickness
6 8 10 12
Fully Grouted 68 92 116 140
16 58 75 92 111
24 53 69 85 102
32 51 65 78 93
40 50 62 75 89
48 49 60 72 85
56 48 58 70 83
64 47 57 69 81
72 46 56 68 80
No Grout 43 50 59 69


Try Our Message Board


Bringing Efficiency to the Construction Industry
EPC Server.com
Copyright © 2001,2002, EPCServer.com All rights reserved. All content in this site is provided 'as is' and no warranty is given as to the accuracy or suitability of any part hereof. No liability will be accepted for any direct or consequential losses, howsoever caused, following the use or misuse of any advice or information, real or implied, provided by this site.