EQUIVALENT WALL THICKNESS FOR GROUTED MASONRY UNITS



The equivalent thickness for masonry walls with hollow units and varying grouted cell spacings are as shown in the following table. All dimensions are in inches. These values are to be used for computing compression and shear stresses parallel to the wall.

Spacing of Grouted Cells Nominal Wall Thickness
6 8 10 12
Fully Grouted 5.62 7.62 9.62 11.62
16 3.70 4.90 5.98 7.04
24 3.13 4.10 4.91 5.70
32 2.85 3.70 4.37 5.02
40 2.68 3.46 4.05 4.62
48 2.57 3.30 3.83 4.35
56 2.49 3.19 3.67 4.16
64 2.42 3.10 3.56 4.01
72 2.38 3.03 3.47 3.90
No Grout 2.00 2.50 2.75 3.00


Try Our Message Board


Bringing Efficiency to the Construction Industry
EPC Server.com
Copyright © 2001,2002, EPCServer.com All rights reserved. All content in this site is provided 'as is' and no warranty is given as to the accuracy or suitability of any part hereof. No liability will be accepted for any direct or consequential losses, howsoever caused, following the use or misuse of any advice or information, real or implied, provided by this site.