PROPERTIES OF REINFORCED MASONRY



As a general rule, the dimensions for hollow Concrete Masonry Units (CMU) may be assumed as shown in above and given in table below. These values will vary with unit type, geographic location, and manufacturer; however; they are considered conservative and are typically used in design calculations.

CMU Nominal Thickness CMU Design Thickness ts tw d1 d2 bw
6 5 5/8 1 1 2.81 -- 7 1/2
8 7 5/8 1 1/4 1 3.81 5.31 7 1/2
10 9 5/8 1 3/8 1 1/8 4.81 7.06 7 1/2
12 11 5/8 1 1/2 1 1/8 5.81 8.81 7 1/2



Try Our Message Board


Bringing Efficiency to the Construction Industry
EPC Server.com
Copyright © 2001,2002, EPCServer.com All rights reserved. All content in this site is provided 'as is' and no warranty is given as to the accuracy or suitability of any part hereof. No liability will be accepted for any direct or consequential losses, howsoever caused, following the use or misuse of any advice or information, real or implied, provided by this site.