REINFORCING BAR TOLERANCES



MAIN REINFORCING

d dimension
Placement Tolerance
Less than or equal to 8"
1/4"
Greater than 8" and Less than 24 inches
3/8"
Greater or equal to 24 inches
1/2"


Clear Cover may not be reduced more than 1/3 of that specified



Tolerance for ends of bars and longnitudinal location of bends - 2" except at discontinous ends of members where the tolerance = 1/2"



Try Our Message Board


Bringing Efficiency to the Construction Industry
EPC Server.com
Copyright © 2001,2002, EPCServer.com All rights reserved. All content in this site is provided 'as is' and no warranty is given as to the accuracy or suitability of any part hereof. No liability will be accepted for any direct or consequential losses, howsoever caused, following the use or misuse of any advice or information, real or implied, provided by this site.