EPC Server - Your Resource for Engineering, Procurement, and Construction Support
USER IS NOT LOGGED IN
Log In Registration To Do List Online Analysis Developers Partnership About EPC Server



This application is not certified View Bug Report Submit Bug

REINFORCING BAR SPACING






Clear Spacing for flexure members - one bar diameter but not less than 1"

Spirally reinforced and tied compression members - 1 1/2 bar diameters but not less than 1 1/2"

Pretensioning Steel - 4 diameters

For Bundled bars, the diameter of a single bar of equivalent diameter shall be used

Clear distance for all configurations shall also be greater than 4/3 of the maximum aggregate size

Maximum Average Tensile Reinforcing Spacing in Slabs Note: Spacing for slabs shall not exceed 18" or 3 X Slab thickness

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Outside
2"
#4
4 1/2"
60
Outside
2"
#5
4 1/4"
60
Outside
2"
#6
4"
60
Outside
2"
#7
3 3/4"
60
Outside
2"
#8
3 1/2"
60
Outside
2"
#9
3 1/2"
60
Outside
2"
#10
3 1/4"
60
Outside
2"
#11
3"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Outside
1 1/2"
#4
7 1/2"
60
Outside
1 1/2"
#5
6 3/4"
60
Outside
1 1/2"
#6
6 1/2"
60
Outside
1 1/2"
#7
6"
60
Outside
1 1/2"
#8
5 3/4"
60
Outside
1 1/2"
#9
5 1/4"
60
Outside
1 1/2"
#10
5"
60
Outside
1 1/2"
#11
4 3/4"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Outside
1"
#4
14 1/2"
60
Outside
1"
#5
13 1/4"
60
Outside
1"
#6
12"
60
Outside
1"
#7
11"
60
Outside
1"
#8
10"
60
Outside
1"
#9
9 1/4"
60
Outside
1"
#10
8 1/2"
60
Outside
1"
#11
8"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Outside
3/4"
#4
NA"
60
Outside
3/4"
#5
NA"
60
Outside
3/4"
#6
NA"
60
Outside
3/4"
#7
16 1/4"
60
Outside
3/4"
#8
14 1/2"
60
Outside
3/4"
#9
13 1/4"
60
Outside
3/4"
#10
12"
60
Outside
3/4"
#11
11"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Inside
2"
#4
8"
60
Inside
2"
#5
7 1/2"
60
Inside
2"
#6
7"
60
Inside
2"
#7
6 3/4"
60
Inside
2"
#8
6 1/2"
60
Inside
2"
#9
6"
60
Inside
2"
#10
5 3/4"
60
Inside
2"
#11
5 1/2"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Inside
1 1/2"
#4
13 1/4"
60
Inside
1 1/2"
#5
12 1/4"
60
Inside
1 1/2"
#6
11 1/2"
60
Inside
1 1/2"
#7
10 3/4"
60
Inside
1 1/2"
#8
10"
60
Inside
1 1/2"
#9
9 1/2"
60
Inside
1 1/2"
#10
9"
60
Inside
1 1/2"
#11
8 1/2"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Inside
1"
#4
14 1/2"
60
Inside
1"
#5
13 1/4"
60
Inside
1"
#6
12"
60
Inside
1"
#7
11"
60
Inside
1"
#8
10"
60
Inside
1"
#9
9 1/4"
60
Inside
1"
#10
8 1/2"
60
Inside
1"
#11
8"

Maximum Average Tensile Reinforcing Spacing in Beams

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Outside
3"
#4
3"
60
Outside
3"
#5
3 1/4"
60
Outside
3"
#6
2 1/4"
60
Outside
3"
#7
2 3/4"
60
Outside
3"
#8
2 1/2"
60
Outside
3"
#9
2 1/2"
60
Outside
3"
#10
2 1/4"
60
Outside
3"
#11
NA

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Outside
2"
#4
6 1/4"
60
Outside
2"
#5
6"
60
Outside
2"
#6
5 3/4"
60
Outside
2"
#7
5 1/4"
60
Outside
2"
#8
5"
60
Outside
2"
#9
4 3/4"
60
Outside
2"
#10
4 1/2"
60
Outside
2"
#11
4 1/2"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Outside
1 1/2"
#4
10 1/2"
60
Outside
1 1/2"
#5
9 3/4"
60
Outside
1 1/2"
#6
9 1/4"
60
Outside
1 1/2"
#7
8 1/2"
60
Outside
1 1/2"
#8
8"
60
Outside
1 1/2"
#9
7 1/2"
60
Outside
1 1/2"
#10
7"
60
Outside
1 1/2"
#11
6 3/4"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Inside
3"
#4
5 1/4"
60
Inside
3"
#5
5"
60
Inside
3"
#6
5"
60
Inside
3"
#7
4 3/4"
60
Inside
3"
#8
4 1/2"
60
Inside
3"
#9
4 1/2"
60
Inside
3"
#10
4 1/4"
60
Inside
3"
#11
4"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Inside
2"
#4
11 1/4"
60
Inside
2"
#5
10 1/2"
60
Inside
2"
#6
10"
60
Inside
2"
#7
9 1/2"
60
Inside
2"
#8
9"
60
Inside
2"
#9
8 1/2"
60
Inside
2"
#10
8 1/4"
60
Inside
2"
#11
7 3/4"

Yield Strength
Exposure
Cover
Bar Size
Average Spacing
60
Inside
1 1/2"
#4
18 3/4"
60
Inside
1 1/2"
#5
17 142"
60
Inside
1 1/2"
#6
16"
60
Inside
1 1/2"
#7
15"
60
Inside
1 1/2"
#8
14 1/4"
60
Inside
1 1/2"
#9
13 1/2"
60
Inside
1 1/2"
#10
12 1/2"
60
Inside
1 1/2"
#11
12"



Try Our Message Board


Bringing Efficiency to the Construction Industry
EPC Server.com
Copyright © 2001,2002, EPCServer.com All rights reserved. All content in this site is provided 'as is' and no warranty is given as to the accuracy or suitability of any part hereof. No liability will be accepted for any direct or consequential losses, howsoever caused, following the use or misuse of any advice or information, real or implied, provided by this site.