REINFORCING BAR BUNDLING




Bundles Must be enclosed by ties or stirrups

Number 14 and Number 18 bars may not be bundled in beams or girders

Cut offs of individual bars in bundles must be staggered at least 40 bar diameters

For Spacing and cover, a unit of bundled bars shall be treated as a single bar with an equivalent Area of the bundled bar configuration

A maximum of 4 bars may be bundled




Try Our Message Board


Bringing Efficiency to the Construction Industry
EPC Server.com
Copyright © 2001,2002, EPCServer.com All rights reserved. All content in this site is provided 'as is' and no warranty is given as to the accuracy or suitability of any part hereof. No liability will be accepted for any direct or consequential losses, howsoever caused, following the use or misuse of any advice or information, real or implied, provided by this site.